Ingenico Tetra Setup for PDC
Home » Payment Gateway Documentation » Payment Gateway Setup » Payment Device Setup » Payment Device Firmware Setup » Ingenico Tetra Setup for PDC
Table of Contents
Key Injection
Your device should come with all necessary keys injected. In rare instances, you may need to initialize the key injection slots.
IF YOU SEE KEY INJECTION SCREEN, like the one on the right , select 3 (No Key Injection). If asked, Press 1 to Delete Key and then create a new Key Index. Eventually, you should see the message This Lane Is Closed
→If after pressing 3, the pin pad cycles back to the original KEY INJECTION screen with options 0-3, the pin pad is faulty and needs to be replaced.
Minimum UPP Version
Ingenico Operating System/Firmware is call Universal Payment Protocol (UPP). You can see the version of UPP on bootup screen. Please, make sure to use the UPP version 5.0.8 or higher.
Enter Configuration
Here are the steps to configure the Ingenico Tetra device:
- Press 2-6-3-4-F
- Enter TDA->Configuration
- Communication->Select Comm. Type->Ethernet->Press Green key( OK )
Set Communication Type
In this example we will be using Ethernet communications.
- Communication->Select Comm. Type->Ethernet->Press Green key( OK )
Set Communication Method
This is an important part of the communication setup. There are two Communication Methods: CLIENT and SERVER. This one is a bit confusing, as Ingenico defines the roles in reverse of the convention.
SERVER is used when Payment Terminal connects to the Cloud9 Payment Gateway with the help of the Payment Device Controller
- Communication->Ethernet Settings->Connection Method->Server
- Press Green key( OK )
Skip Host Setup
This step is only necessary for CLIENT (NO PDC) mode.
- Communication->Ethernet Settings->HostIP Address->xx.xx.xx.xx
- Press Green key( OK )
- Configuration->Communication->Ethernet Settings->IP PORT->xxxxx
- Press Green key( OK )
Record Payment Device IP Address for PDC use
- Communication->Ethernet Settings->IP Port->xx.xx.xx.xx
- Record this IP Address. You will need it to setup your locally installed Payment Device Controller (PDC)
- Press Green key( OK )
Set SSL Mode
- Communication->Ethernet Settings->SSL->On
- Press Green key( OK )
Reboot and Refresh
This step will start an automated reboot and refresh process.
- Press RED(X-Cancel) key to return to previous menu
- Keep pressing RED(X-Cancel) until you see a prompt “Save and Reboot?”-> Choose Yes
- Press Green key( OK )
- Device will reboot…
- Device will display “This lane closed”…
- Wait until the device reboots by itself.