=How add Certificate to Tetra=
+
=Ingenico Tetra IP & PDC Setup=
For instance, if we are adding '''Lane 3000'''
+
[[https://c9pg.com/docs/PaymentDevices/Ingenico/Tetra/IngenicoTerminalSetup.pdf  Ingenico IP Setup]]
Here are the steps to configure the device:
 
1.Press 2-6-3-4-F
 
2.Enter TDA->Configuration
 
3.Communication->Select Comm. Type->Ethernet->Press Green key( OK )
 
4.Communication->Ethernet Settings->Connection Method->Client->Press Green key( OK )
 
5.Communication->Ethernet Settings->HostIP Address->34.213.177.219->Press Green key( OK )
 
6.Communication->Ethernet Settings->IP Port->12009->Press Green key( OK )
 
7.Communication->Ethernet Settings->SSL->None->Press Green key( OK )
 
8.Pressing RED(X-Cancel) key will return to previous menu...press it until it will prompt "Save and Reboot?"-> Choose Yes->Press Green key( OK )
 
Device will reboot...Enter "This lane closed"...leave it for a few seconds and it will start to download configuration and then it will reboot by itself
 
 
 
May need to add Attachment to C9pg folder on the workstation profile
 
certificate\PinPad\client\CLIENT_CERT.PEM
 
 
 
There should be a distinct  setup for Tetra make sure to check profile PDC/CONF com.jijesoft.gateway.pinpadNameList.ini
 
[DeviceOnDemand]
 
IWL258=true
 
L5000=true
 
L3000=true
 
IF you dont see the L3000=true then add it in there same as above.
 
 
 
They should be running PDC 2.01.07 for this function to work.
 
After the above open the PDC on the user profile and enter the IP of the device then test the PDC. You should be able to run a transaction on the terminal and see it on cloud9.
 