Here are the steps to configure the device:
 
Here are the steps to configure the device:
 
1.Press 2-6-3-4-F
 
1.Press 2-6-3-4-F
Line 26: Line 27:
 
They should be running PDC 2.01.07 for this function to work.
 
They should be running PDC 2.01.07 for this function to work.
 
After the above open the PDC on the user profile and enter the IP of the device then test the PDC. You should be able to run a transaction on the terminal and see it on cloud9.
 
After the above open the PDC on the user profile and enter the IP of the device then test the PDC. You should be able to run a transaction on the terminal and see it on cloud9.
 +
</pre>

Revision as of 21:48, 16 April 2020




Cloud9 Payment Gateway Documentation. This site can also be reached at http://docs.cloud9paymentgateway.com

How add Certificate to Tetra

For instance, if we are adding Lane 3000

Here are the steps to configure the device:
1.Press 2-6-3-4-F
2.Enter TDA->Configuration
3.Communication->Select Comm. Type->Ethernet->Press Green key( OK )
4.Communication->Ethernet Settings->Connection Method->Client->Press Green key( OK )
5.Communication->Ethernet Settings->HostIP Address->34.213.177.219->Press Green key( OK )
6.Communication->Ethernet Settings->IP Port->12009->Press Green key( OK )
7.Communication->Ethernet Settings->SSL->None->Press Green key( OK )
8.Pressing RED(X-Cancel) key will return to previous menu...press it until it will prompt "Save and Reboot?"-> Choose Yes->Press Green key( OK )
Device will reboot...Enter "This lane closed"...leave it for a few seconds and it will start to download configuration and then it will reboot by itself

May need to add Attachment to C9pg folder on the workstation profile 
certificate\PinPad\client\CLIENT_CERT.PEM

There should be a distinct  setup for Tetra make sure to check profile PDC/CONF com.jijesoft.gateway.pinpadNameList.ini
[DeviceOnDemand]
IWL258=true
L5000=true
L3000=true
IF you dont see the L3000=true then add it in there same as above.

They should be running PDC 2.01.07 for this function to work.
After the above open the PDC on the user profile and enter the IP of the device then test the PDC. You should be able to run a transaction on the terminal and see it on cloud9.